FXPV Series DC Surge Protector | WELTRUS

FXPV Series DC Surge Protector

Professional Surge Protection Solutions for Solar PV Systems – 600V to 1500V DC

FXPV DC Surge Protector
Main View
Front View
Side View
Type 1+2 / Type 2 DC SPD

FXPV Series

Photovoltaic DC Surge Protector (600V-1500V)

Key Features

  • Type 1+2 and Type 2 DC surge protection
  • 20kA nominal discharge current
  • 40kA maximum discharge current
  • Voltage ratings: 600V, 1000V, 1200V, 1500V
  • IEC 61643-31, EN 61643-31, UL 1449 compliant
  • Designed for solar PV systems
  • Pluggable design for easy maintenance
  • Thermal protection with status indication
  • Fast response time (< 25ns)
  • Protection mode: DC+-PE, DC–PE, DC+-DC-
IEC 61643-31
EN 61643-31
UL 1449

The FXPV Series DC Surge Protector is specifically engineered for photovoltaic (PV) systems, providing Type 1+2 and Type 2 surge protection for high-voltage DC applications. Available in voltage ratings of 600V, 1000V, 1200V, and 1500V, the FXPV series offers comprehensive protection for solar string boxes, inverters, and PV combiner boxes. With 20kA nominal and 40kA maximum discharge current, these SPDs deliver robust protection against lightning-induced surges and switching transients. The pluggable modular design allows for quick and easy module replacement without disconnecting the wiring, ensuring minimal downtime. Compliant with IEC 61643-31, EN 61643-31, and UL 1449 4th Edition standards, the FXPV series is ideal for residential, commercial, and utility-scale solar installations.

FXPV Series Technical Specifications

Available Voltages

600V
FXPV-600 Series
1000V
FXPV-1000 Series
1200V
FXPV-1200 Series
1500V
FXPV-1500 Series
Parameter Type 1+2 (FXPV-12.5B) Type 2 (FXPV-XXX)
Standard IEC 61643-31, EN 61643-31, UL 1449 IEC 61643-31, EN 61643-31, UL 1449
Type Class I+II / Type 1+2 Class II / Type 2
DC Voltage Options 600V, 1000V, 1200V, 1500V 600V, 1000V, 1200V, 1500V
Nominal Discharge Current (In) 20 kA (8/20µs) 20 kA (8/20µs)
Maximum Discharge Current (Imax) 40 kA (8/20µs) 40 kA (8/20µs)
Impulse Discharge Current (Iimp) 12.5 kA (10/350µs)
Total Discharge Current (ITotal) 12.5 kA (10/350µs), 40 kA (8/20µs) 40 kA (8/20µs)
Voltage Protection Level (Up) ≤2200V / ≤4000V / ≤4400V / ≤5200V ≤2200V / ≤4000V / ≤4400V / ≤5200V
Response Time < 25 ns < 25 ns
Short-Circuit Current Rating 2000 A 2000 A
Protection Mode DC+-PE, DC–PE, DC+-DC- DC+-PE, DC–PE, DC+-DC-
Operating Temperature -40°C to +70°C -40°C to +70°C
Mounting 35 mm DIN Rail 35 mm DIN Rail
Degree of Protection IP20 (built-in) IP20 (built-in)
Conductor Cross Section (max) 35 mm² (Solid), 25 mm² (Flexible) 35 mm² (Solid), 25 mm² (Flexible)

Applications

Solar PV Systems

Protection for photovoltaic installations, string boxes, and combiner boxes in residential, commercial, and utility-scale projects

Inverter Protection

Surge protection for inverters and power conversion equipment in solar energy systems

Telecommunications

Protection for DC power distribution in telecom infrastructure and communication systems

Industrial DC Systems

Protection for industrial control systems, DC motor drives, and other 220V DC applications

Quick Specifications

  • Voltage: 600-1500V DC
  • In: 20 kA
  • Imax: 40 kA
  • Type: Type 1+2 / Type 2
  • Standard: IEC 61643-31
  • Application: Solar PV

Voltage Ratings

  • • DC+ – PE
  • • DC- – PE
  • • DC+ – DC-

Certifications

IEC 61643-21/31

Low-voltage surge protective devices

EN 61643-21/31

European Standard

UL 1449

UL Standard for SPD

Contact Information

Hangzhou Weltrus New Energy Technology Co., Ltd.

Block D, Ocean International Center
333 Yuanjian Street, Hangzhou
Zhejiang, China

Tel/WhatsApp: +86 13735502672

Email: [email protected]

Contact Us

WhatsApp

+86-13735502672

Talk to our experts

  • We will contact you within 12 hours
  • Don’t worry, we hate spam too!